CT/PT Accuracy Class Calibrator (Angle and Ratio Difference Measurement)

GDHG-103 Mutual Inductor CT PT Calibrator Transformer Calibration Device General introductionGDHG-103 CT/PT Calibrator is mainly used to calibrate CT/PT with accuracy class 0.01 to class 10, CT secondary rated current is 5A, 1A and PT secondary rated voltage is 100V, 100/3V, 150V(100/3V,220V). The test result is shown direc

Featured Products

CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)


GDHG-103 Mutual Inductor CT PT Calibrator Transformer Calibration Device

CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)
 

General introduction

GDHG-103 CT/PT Calibrator is mainly used to calibrate CT/PT with accuracy class 0.01 to class 10, CT secondary rated current is 5A, 1A and PT secondary rated voltage is 100V, 100/3V, 150V(100/3V,220V). The test result is shown directly by figure.

 

Features

  • Display, save and print data.
  • Automatic measurement, using difference value measurement method and direct measurement error.
  • Automatic polarity judgment, automatically determine the polarity within 2%-20%
  • Automatically switch range according to measurement data.
  • Strong adaptability for power supply.
  • 320*240 LCD screen with back light.
  • AC sampling and full data processing.
  • With data management function. It can be connected with PC.
  • Save and check measurement result. Data will not lose after power off .

Optional components:

  • Standard PT
  • Standard CT
  • Self-boosting standard transformer
  • Standard CT with current injector
  • Control unit with double voltage regulator
  • Inductive divider
  • PT load case
  • CT load case

Specifications

 

Measurement Range

In-phase component(%): 0.0001-200, resolution 0.0001

Quadrature component(min): 0.001-700.0, resolution 0.001

Impedance(Ω): 0.001-20.0, resolution 0.0001

Admittance(ms): 0.0001-20.0, resolution 0.0001

Accuracy

Basic error

In-phase component: ΔX=±(X×2%+Y×2%)±Dx

Quadrature component: ΔY=±(X×2%+Y×2%×34.48)±Dy

X,Y-- Display value of instrument

Dx, Dy-- Quantization error

lError of Percent table: 1.5% (1.0% for option)


CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)
CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)
CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)
CT/PT Accuracy Class Calibrator(Angle and ratio difference measurement)
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours
none" stroke-linecap="round" stroke-linejoin="round" class="css-i6dzq1">
CT/PT Accuracy Class Calibrator (Angle and Ratio Difference Measurement)
  • Ultrasonic fuel level sensor water tank high precision pressure sensor level measurement
  • Electronic Test and Measurement Instrument Phase Angle Multimeter
  • Multifunctional goniometer template tool plastic measuring four-sided ruler manual precise measuring tool
  • Floor gloss meter (GMS/GM60) marble multi-angle measurement
  • Boom angle position and length measurement for Grove Rt cranes
  • Easy-to-use fast measurement infrared measurement technology non-contact measurement thermometer
  • water level sensor meter water level measurement water storage tank sensor
  • Contact us

    Please feel free to give your inquiry in the form below We will reply you in 24 hours